GBP/USD1.2734▲ 0.0042|EUR/USD1.0851▼ 0.0019|GBP/EUR1.1736▲ 0.0028|DXY104.21▼ 0.18|FTSE 1008,224.31▲ 18.42|GBP/USD1.2734▲ 0.0042|EUR/USD1.0851▼ 0.0019|GBP/EUR1.1736▲ 0.0028|DXY104.21▼ 0.18|FTSE 1008,224.31▲ 18.42|
United StatesAdvanced Life SciencesAdvanced Life Sciences
All Raytor products
RT814 Automated Transdermal Diffusion System
Manufacturer: RaytorFamily: Transdermal Diffusion
RT814

RT814 Automated Transdermal Diffusion System

Raytor RT814 Automated Transdermal Diffusion System is a fully automatic 14-position transdermal diffusion cell (Franz cell) system that uses innovative technology and modular design. It consists of multiple modules such as a Franz diffusion cell device, an automatic sampling module, and a medium thermostat. Based on achieving automation, the performance of the equipment also meets the test requirements of the European Pharmacopoeia (EP9.0): General rule<2.9.4 Dissolution test for transdermal patches> and the United States Pharmacopoeia: General rule <1724> Semisolid Drug Products - Performance Tests.

  • Flexible sampling methods
  • Real-time monitoring and recording
  • Integrated diffusion cell system
  • Independent temperature control for all cells

Key features

Diffusion cell integrated structure.

The diffusion cell is an integrated glass structure to reduce the risk of leakage

Automatically remove air bubbles.

The mechanical structure automatically exhausts the residual bubbles in the diffusion pool to ensure the accuracy of the test data.

Separate pipeline design.

Each diffusion cell has corresponding pipelines and pumps to avoid cross contamination during the test.

Two groups independent design.

Two groups of diffusion cells can be used for testing at the same time without interfering with each other.

Sampling method is optional.

The equipment can meet two sampling methods: partial sampling or full sampling. The sampling method can be flexibly selected according to the test requirements.

Applications

Meet the test requirements of USP<1724> for in vitro release and in vitro permeation of semi-solid preparations

  • creams
  • ointments
  • patches
  • gels

Technical specifications

Automatic Sampling Transdermal Diffusion System
Diffusion cell position
7×2
Sampling channels
14
Diffusion cell volume
9, 10, 12mL
Sampling times
≤24
Sampling range
1~10ml (including full sampling and partial sampling)
Temperature range
room temperature~50℃
Heating method
dry heating
Temperature error
<±0.5℃
Speed range
200~900rpm
Speed error
<±10%
Maximum sampling time
9999mins
—
Automatic bubble removal
Official Raytor product page

Ready to specify a Raytor system?

Tell us your method, dosage form and throughput. Our team will prepare a quotation.