RT800 Automated Transdermal Diffusion System
Manufacturer: RaytorFamily: Transdermal Diffusion
RT800

RT800 Automated Transdermal Diffusion System

RT800 Automated Transdermal Diffusion System is consisting of Franz diffusion cells and an automatic sampling device. It complies with the European Pharmacopoeia (EP9.0): General rules<2.9.4 Dissolution test for transdermal patches> and the United States Pharmacopoeia: General rules<1724> Semisolid Drug Products - Performance Tests requirements for in vitro release tests (IVRT) and in vitro permeation tests (IVPT). Through automated operations, it can achieve complex cleaning, sampling, and refilling functions to improve the accuracy of test results.

  • Complies with regulation USP<1724>
  • 7 channels synchronized automatic sampling
  • Meet audit trail requirements
  • Shorter pipeline design effectively reduces sample residue

Key features

Compliant diffusion cell style

Compliant with the diffusion cell style recommended by USP<1724>

Shorter pipeline design

The sampling pipeline is shorter, which can reduce the risk of pipeline residue.

The number of diffusion cell: 6+1

A group can conduct up to 7 diffusion cell tests, so a blank group can be designed to exclude other interference.

Simultaneous sampling design.

When sampling, the diffusion pools in the same group will be sampled at the same time to reduce the impact of sampling time on the test results

Two groups independent design

The two groups of diffusion cells can be used for testing at the same time without interfering with each other.

Filling point design

The filling point is marked on the diffusion cell. After removing the bubbles, the medium is injected to the filling point to ensure that no bubbles are generated in the future.

Applications

Meet the test requirements of USP<1724> for in vitro release and in vitro permeation of semi-solid preparations

  • creams
  • ointments
  • patches
  • gels

Technical specifications

Automatic Sampling Transdermal Diffusion System
Diffusion cell position
7×2
Sampling channels
7
Diffusion cell volume
10ml, 15ml, 20ml, 25ml, 30ml, 40ml
Sampling times
≤24
Sampling range
0.2~1.5ml
Temperature error
≤±0.5℃
Temperature range
room temperature~45℃
Speed range
200~900rpm
Speed error
<±10%
Heating method
dry heating
—
Manual bubble exhaust
Maximum sampling time
9999mins