NCE Micro Dissolution and Permeation Analyzer
Manufacturer: RaytorFamily: New Compound Analyzer
NCE DP

NCE Micro Dissolution and Permeation Analyzer

Real-time concentration monitoring is possible through the advanced technology platform called NCE Micro Dissolution and Permeation Analyzer. The system performs dissolution and permeation analysis through its biological model coupled with its optical fiber system which duplicates human body procedures to achieve precise measurements. The system provides precise absorbance monitoring to enhance biopharmaceutical classification. Data accuracy relies on Accurate Inside technology and graphical results strengthen analysis effectiveness. The system lowers the consumption of test samples which helps maximize experimental resource utilization.

  • Exclusive patented Accurate Inside algorithm
  • Real-time monitoring of absorbance
  • Graphical representation of experimental results
  • Reduce the amount of sample required for the experiment

Key features

Real-time monitoring

The device is equipped with 6 optical fibers, which can monitor the concentration changes of samples in real time during the experiment.

Medium switching module

For experiments that require medium switching, the medium switching module can automatically inject the medium at a specific time to complete the medium switching operation.

Bionic membrane

Bionic membrane is used to construct a permeation model to simulate the absorption of drugs by small intestinal epithelial cells.

Auxiliary analysis software

Auxiliary analysis software can analyze data results and compare different experimental results, making the experimental results clear and easy to understand.

Applications

  • Intrinsic Dissolution Rate Test
  • PH Shift Model
  • Permeation Model

Technical specifications

Dissolution&Permeation Analyzer
Wavelength range
200~750nm
Absorbance linear range
0.01~3AU
Wavelength accuracy
1nm
Detector type
Deuterium lamp
Absorbance accuracy
±0.001AU
Minimum acquisition frequency
1 second/time
Reactor channel
6
Fiber channel
6
Light source life
>1000h
Room temperature range
room temperature~40℃
Temperature error
±0.5℃
Speed range
100~1000rpm
Speed resolution
1rpm
Liquid addition accuracy
<1%
Official Raytor product page

Ready to specify a Raytor system?

Tell us your method, dosage form and throughput. Our team will prepare a quotation.