Technical Catalog
Search analytical instrument parts
Search by part number, manufacturer, model, or category. Every listing includes technical details and a direct Request a Quote form.
Showing 61–120 of 299 products
Updating…
Agilent
G1312-60067
Outlet valve, 600 bar. For 1100, 1200, 1260 Infinity LC pumps.
High-pressure 600 bar outlet check valve assembly with integrated seal for Agilent 1100, 1200, 1220, and 1260 Infinity LC pumps, ensuring accurate solvent delivery and backpressure control.
Request a quote →
Agilent
G1312-60071
Purge Valve long with PTFE frit, 600bar
Manual purge valve assembly (long) with integrated PTFE frit rated up to 600 bar. Designed for priming and purging liquid chromatography pump systems while protecting the flow path from particulate contamination.
US$ 532.00R$ 7,600.00
Request a quote →
Agilent
G1313-68709
Autosampler Start Up Kit. extended PM Kit for G1313A/29A Autosamplers
Agilent Autosampler Start Up Kit for G1313A and G1329A autosamplers. Includes essential consumables for routine startup and preventative maintenance, such as a Vespel rotor seal, needle assembly, PEEK needle seat, metering seals, and finger caps.
Request a quote →
Agilent
G1313-68719
Preventive Maintenance Kit for 1200/1260 Infinity Series Autosampler (G1329B)
Preventive Maintenance Kit for Agilent 1200/1260 Infinity Series Autosamplers (G1329B). Contains essential OEM replacement components required to perform standard preventative maintenance and maintain peak chromatographic sampling performance.
US$ 865.01
Request a quote →
Agilent
G1313-68730
Preventive Maintenance Kit for 1100/1200 Series Autosamplers (G1313A/G1329A)
Preventive Maintenance Kit for Agilent 1100 and 1200 Series standard autosamplers (G1313A, G1329A). Contains essential replacement parts including a Vespel rotor seal, needle assembly, PEEK needle seat, piston seal, and finger caps to ensure operational reliability and sampling precision.
Request a quote →
Agilent
G1313-87201
Needle assembly
Agilent G1313-87201 is a standard 100 µL sampling needle assembly designed for Agilent 1100, 1120, 1200, 1220, and 1260 Infinity Series HPLC autosamplers (G1313A, G1329A/B). It pierces sample vial septa and draws liquid sample for high-pressure chromatographic injection.
Request a quote →
Agilent
G1313-87301
Capillary stainless steel 0.25 x 160 mm S/SH ps/ps
Agilent stainless steel capillary tubing (0.25 mm ID x 160 mm length) with pre-swaged S/SH Swagelok fittings, designed for connecting the injection valve to the metering device in Agilent 1100, 1200, and 1260 Series HPLC autosamplers.
Request a quote →
Agilent
G1314-60100
Long-life deuterium VWD lamp.
Long-life deuterium UV lamp designed for Agilent variable wavelength detectors (VWD) in HPLC systems. Delivers high light intensity, low baseline noise, and minimal drift for accurate chromatographic analysis without an RFID tag.
US$ 719.99R$ 6,500.01
Request a quote →
Agilent
G1314-60101
InfinityLab long-life deuterium VWD lamp, with RFID tag.
InfinityLab long-life deuterium VWD lamp equipped with an integrated RFID tag. Designed for Agilent variable wavelength detectors in HPLC systems to deliver continuous, high-sensitivity UV detection with minimal noise and drift.
US$ 750.01R$ 6,499.99
Request a quote →
Agilent
G1314-60186
Standard Flow Cell VWD 10mm 14ul. RFID
Standard flow cell featuring a 10 mm optical path length, 14 µL cell volume, 40 bar pressure rating, and integrated RFID tag. Designed for Agilent Variable Wavelength Detectors (VWD) in LC systems to deliver precise UV absorbance measurements and automated cell parameter recognition.
Request a quote →
Agilent
G1314-69060
Agilent HPLC VWD Optical Unit Ref
Agilent G1314-69060 is a refurbished exchange optical unit assembly designed for Agilent 1100 and 1200 Series Variable Wavelength Detectors (VWD). It forms the optical core of the detector, housing the deuterium lamp mount, optical lenses, monochromator, and photodiode assemblies.
Request a quote →
Agilent
G1321-60005
Flow cell, 8 µL, 20 bar
Standard quartz flow cell featuring an 8 µL internal volume, 20 bar maximum pressure limit, and pH 1.0–9.5 chemical compatibility. Designed for Agilent HPLC fluorescence detectors (FLD) to deliver high-sensitivity optical detection in liquid chromatography workflows.
Request a quote →
Agilent
G1322-60003
Solenoid valve, G1322A
3-port 24VDC vacuum degasser solenoid valve for Agilent HPLC degassing modules. Regulates vacuum level inside the degasser assembly to remove dissolved gases from LC mobile phase solvents.
Request a quote →
Agilent
G1329-87017
Needle seat, PEEK, 0.17 mm ID capillary.
Standard PEEK needle seat with 0.17 mm ID capillary for Agilent HPLC autosamplers. Connects the autosampler needle to the injection valve capillary flow path and ensures a leak-free pressure seal during sample injection.
Request a quote →
Agilent
G1362-27700
Purge Valve
Agilent purge valve (PN G1362-27700) for Refractive Index (RI) detector modules. Internal replacement component used to control solvent flow paths during purging and cell flushing routines in HPLC RID modules.
Request a quote →
Agilent
G1367-87012
Low Carry Over Needle Seat 0.12 Capillary
Low carryover PEEK needle seat with 0.12 mm ID capillary for Agilent 1200 / 1260 Infinity Series well plate autosamplers (G1367D, G1367E), rated up to 600 bar.
Request a quote →
Agilent
G1367-87101
Needle seat, Vespel, 0.17 mm ID capillary, 2.3 µL, for G1367A, G1367B well plate sampler.
Needle seat with Vespel material, 0.17 mm ID capillary, and 2.3 µL internal volume, designed for Agilent G1367A and G1367B well plate samplers.
Request a quote →
Agilent
G1367-87104
Needle seat, without capillary, for G1367 well plate sampler
Agilent G1367-87104 is an OEM needle seat assembly without capillary designed for Agilent G1367 well plate autosamplers. Rated up to 600 bar, it ensures a reliable, leak-tight seal with the autosampler needle during HPLC sample injections.
Request a quote →
Agilent
G1367-87201
Needle assembly, for G1367A, G1367B well plate sampler.
Agilent G1367-87201 is a stainless steel needle assembly designed for G1367A and G1367B Well Plate Samplers in Agilent 1100 and 1200 Series HPLC systems. Compatible with Vespel needle seat G1367-87101.
Request a quote →
Agilent
G1367-87202
Needle assembly, for G1367C well plate sampler.
Stainless steel needle assembly designed for Agilent G1367C and G1367D well plate samplers in 1200 Series HPLC systems.
Request a quote →
Agilent
G1377-87101
Needle seat, for G1377 µ-well plate sampler
Needle seat (without capillary) for Agilent 1100/1200 micro well-plate autosamplers. Designed for precision needle seating and low-carryover liquid transfer in micro-scale and capillary HPLC applications.
Request a quote →
Agilent
G1530-67950
Heater/sensor assembly for FID, TCD, NPD
Heater/sensor assembly for FID, TCD, NPD, and split/splitless (S/SL) GC valves and detectors. Integrates a heating element and temperature sensor to ensure accurate temperature control in Agilent gas chromatography systems.
Request a quote →
Agilent
G3160-0884
Heatsink Fan for G1330B
The Agilent 3160-0884 (cataloged as G3160-0884) is a heatsink cooling fan for the Agilent G1330B ALS (Autosampler) Thermostat. It ensures thermal regulation and heat dissipation for Peltier cooling elements in HPLC sample temperature control.
Request a quote →
Agilent
G4212-60007
Max-Light Cartridge Cell (60 mm, V(s) 4.0 µL).
The Agilent InfinityLab Max-Light Cartridge Cell (60 mm, 4.0 µL) is a high-sensitivity HPLC flow cell using optofluidic waveguide technology with a 60 mm optical path length and 4.0 µL effective volume, delivering superior signal-to-noise ratio for trace-level UV detection.
US$ 3,200.00R$ 35,600.00
Request a quote →
Agilent
G4212-69040
EXCH-Optical Unit G4212A VSA
Agilent exchange optical unit assembly for the G4212A Diode Array Detector (DAD) with Variable Slit Architecture (VSA). Serves as a replacement optical bench module in Agilent 1260/1290 Infinity HPLC systems.
Request a quote →
Agilent
G4220-20020
Gold seal
Internal gold seal for Agilent 1290 Infinity LC pump outlet valve assemblies (G4220-60028 and G4220-60128), engineered for ultra-high pressure LC applications.
Request a quote →
Agilent
G4220-60022
Passive inlet valve Valve, 1200 bar, 1300 bar.
The Agilent G4220-60022 is a passive inlet valve with integrated seal rated for 1200 bar and 1300 bar operation in Agilent 1290 Infinity LC pumps. It restores proper inlet valve functionality and ensures consistent solvent flow and pump pressure.
Request a quote →
Agilent
G4220-60028
Outlet valve, 1300 bar. For 1290 Infinity LC pumps. Outlet valve with integrated seal
Agilent G4220-60028 is an OEM outlet check valve with an integrated seal, pressure-rated to 1300 bar. Designed for Agilent 1290 Infinity LC pump heads, it prevents backflow and maintains system pressure integrity in ultra-high-performance liquid chromatography (UHPLC) applications.
Request a quote →
Agilent
G4226-87030
Needle seat, ultra low dispersion, for G4226A autosampler
Ultra low dispersion (ULD) needle seat assembly designed for Agilent G4226A autosamplers and 1290 Infinity LC systems, providing minimal extra-column volume for high-resolution UHPLC sample injection.
Request a quote →
Agilent
G4226-87201
Needle assembly, for G1367D, G1367E well plate sampler.
Agilent needle assembly (G4226-87201) designed for well plate samplers and autosamplers in HPLC systems, ensuring precise sample aspiration and dispensing with minimal carryover.
Request a quote →
Agilent
G4267-87201
Needle assembly, for G7167 Multisampler.
Agilent standard needle assembly (PN G4267-87201) designed for G7167 Multisamplers in 1260 and 1290 Infinity II LC Systems. Compatible with high-pressure PEEK needle seat G4267-87012 for precise, leak-free sample injection.
Request a quote →
Agilent
G4556-67011
Standard preventative maintenance kit, for 7697A
Standard preventative maintenance kit designed for the Agilent 7697A Headspace Sampler. Contains essential replacement components including a deactivated sample probe and 1.00 mL headspace sample loop.
Request a quote →
Agilent
G4556-67012
Enhanced preventative maintenance kit, 7697A
Enhanced preventative maintenance kit for the Agilent 7697A Headspace Sampler. Contains factory-recommended consumables and wear parts—including valve rotor, inlet liner, 1 mL sample loop, sample probe, and transfer line—to maintain optimal chromatographic performance and prevent downtime.
Request a quote →
Agilent
G5042-6461
Tubing, PEEK, 1.6 mm od, 0.13 mm id, 5 m. Red
Red color-coded PEEK tubing for HPLC and LC/MS liquid fluidics. Features 1.6 mm (1/16 in) outer diameter, 0.13 mm (0.005 in) inner diameter, and 5 meters total length.
Request a quote →
Agilent
G5061-3356
Sensor, leak
Agilent HPLC Leak Sensor Assembly (PN 5061-3356 / G5061-3356) for Agilent LC modules. Designed to detect solvent leaks inside instrument housings, triggering error alerts to prevent hardware damage and ensure operational safety.
Request a quote →
Agilent
G5062-2418
Stainless steel fittings with short screw (S), 10/pack.
Agilent stainless steel fittings with short screws (1.6 mm ID / 1/16 in OD), supplied in a pack of 10. Includes 10 short fitting screws (9.5 mm length), 10 front ferrules, and 10 back ferrules for Swagelok 1/16 in HPLC capillary connections.
Request a quote →
Agilent
G5062-2484
Seal wash gasket, 6/pk.
Pack of 6 replacement seal wash gaskets for Agilent HPLC pump heads. Designed for active/passive seal wash assemblies to seal the wash chamber, prevent buffer salt crystallization, and protect pistons from premature wear.
Request a quote →
Agilent
G5062-8562
Cartridge for Active Inlet Valve, 400 bar
Agilent 400 bar active inlet valve cartridge designed for HPLC solvent delivery pumps. It provides reliable flow control and prevents backflow in Agilent 1050, 1100, 1120, 1200, and 1260 Infinity LC systems.
Request a quote →
Agilent
G5063-6589
Piston seal, PTFE c/ 2 uni
Black PTFE replacement piston seal with 316 stainless steel spring (2/pack) for Agilent LC pumps and autosamplers. Designed to maintain pressure stability and routine pump performance during preventive maintenance.
Request a quote →
Agilent
G5067-4728
Seal cap.
Agilent purge valve seal cap assembly designed to maintain manual purge valve integrity, ensure a leak-tight seal during analytical runs, and support reliable LC pump performance across Agilent HPLC systems.
Request a quote →
Agilent
G5068-0202
Rotor Seal PEEK-1300bar
PEEK rotor seal rated to 1300 bar for Agilent HPLC/UHPLC multipurpose valves (5067-4237). Maintenance part for 1260 and 1290 Infinity II/III Flexible Pumps.
Request a quote →
Agilent
G5080-8853
Ferrule, graphite, short, 0.5 mm id, for 0.32 mm columns, 10/pk
Agilent 100% short graphite ferrules (0.5 mm ID, 10/pk) for 0.1–0.32 mm ID capillary columns, offering high-temperature leak-free sealing up to 450 °C for GC inlets and non-MSD detectors.
Request a quote →
Agilent
G5181-3360
ALS SyRInge, 10µl tapered, fixed Needle, 23-26s/42/cone, 6 pc/PAK
Agilent 5181-3360 Gold Standard 10 µL GC autosampler syringes featuring fixed tapered 23-26s gauge needles, 42 mm length, and cone tip style. Supplied in a pack of 6 for Agilent automatic liquid samplers.
Request a quote →
Agilent
G5500-1246
Capillary stainless steel 0.17 x 500
Agilent InfinityLab stainless steel HPLC capillary (0.17 mm ID x 500 mm length) featuring pre-swaged SI fittings on both ends. Designed for low-dead-volume fluidic connections between LC modules such as pumps, multisamplers, and valve heads.
Request a quote →
Agilent
G6500-80115
Syringe, CTC 10 µL, pt 2 Combi/GC-PAL.
Agilent 10 µL fixed-needle autosampler syringe (PN G6500-80115) for CTC CombiPAL, GC PAL, and PAL3 LC HTC/HTS systems. Features a 26s gauge, 51 mm length needle with a point style 2 bevel tip and stainless steel plunger for precise liquid injection.
Request a quote →
Agilent
G7120-68741
Preventive maintenance kit for 1290 Infinity II and III high speed pumps.
Preventive maintenance kit for Agilent 1290 Infinity II and III high-speed pumps and 1290 Infinity Binary pumps with Long Life (LL) or Easy Maintenance (EM) heads. Provides replacement seals, frits, and components required to maintain optimal pump performance and minimize instrument downtime.
Request a quote →
Agilent
G7129-60082
Analytical-Head-Assembly 100ul. 1290 Infinity II
100 µL analytical head assembly for Agilent 1290 Infinity II Vialsamplers. Essential component of the autosampler metering device used for high-precision liquid sample aspiration and injection.
Request a quote →
Agilent
G7129-68740
Preventive maintenance kit for 1260 Infinity II and III vialsampler (G7129A/C)
Preventive maintenance kit for Agilent 1260 Infinity II and III Vialsamplers (G7129A/C). Includes essential wear components such as needle assembly, needle seat, peristaltic pump cartridge, rotor seal, and finger caps to maintain peak autosampler performance.
Request a quote →
Agilent
G7129-87017
Needle seat, PEEK, 0.17 mm ID capillary, for 1290 Infinity II vial sampler
Agilent G7129-87017 is a PEEK needle seat assembly featuring a 0.17 mm ID capillary designed for Agilent 1260 and 1290 Infinity II/III Vialsamplers. It delivers leak-free fluidic coupling between the injection needle and analytical flow path, ensuring accurate sample delivery in HPLC systems.
Request a quote →
Agilent
G7129-87117
Needle seat, Vespel, 0.17 mm id capillary, for 1290 Infinity II and III vialsampler
Agilent Vespel needle seat assembly with 0.17 mm ID capillary for 1260 and 1290 Infinity II/III Vialsamplers. Designed for analytical LC applications up to 600 bar.
Request a quote →
Agilent
G7129-87200
Needle assembly for 1260 Infinity II and III vialsampler
Stainless steel autosampler needle assembly designed for sample aspiration and injection in Agilent 1260 Infinity II and III Vialsamplers (G7129A/G7129C).
Request a quote →
Agilent
G7167-68730
Preventive Maintenance Kit for 1260 Infinity II and III Multisampler
Agilent InfinityLab Preventive Maintenance Kit (PN G7167-68730) for 1260 Infinity II and III Multisamplers. Contains key wear components including sample needle assembly, high-pressure needle seat, rotor seal, and piston seal to ensure reliable injection performance and prevent sample carryover.
Request a quote →
Agilent
UV-VIS
8453 AGILENT 8453 UV VIS (SEMINOVO)
The Agilent 8453 (Model G1103A) is a photodiode-array (PDA) UV-Visible spectrophotometer designed for rapid full-spectrum acquisition (190–1100 nm) in under 1.5 seconds, offering high wavelength accuracy, low photometric noise, and exceptional stability for analytical laboratories.
Request a quote →
Gooneex
0515-4384
Machine screw, M3.0 X 0.50, 12 mm long
Pan head star machine screw (M3.0 x 0.50 mm thread, 12 mm long, stainless steel) for Agilent liquid chromatography autosamplers and sample preparation workstations.
Request a quote →
Gooneex
072043
THERMO
The Thermo Scientific Dionex P/N 072043 is an Electrochemical Detector (EC Detector) Assembly engineered for Dionex ICS-5000 and ICS-6000 Ion Chromatography (IC) systems. It enables sensitive amperometric and coulometric detection of electroactive compounds like carbohydrates and amino acids.
Request a quote →
Gooneex
1.51237.0001
KNURLED NUTS WITH LONG BUSHING AND PVD
Knurled nuts kit with long bushing and 6 PVDF double cones designed for 1/16" O.D. capillary connections to Rheodyne 6-port injection valves in HPLC systems. Manufactured by Supelco / Merck Millipore.
Request a quote →
Gooneex
100-2000
COLUNA GC USIL FC
Agilent J&W custom capillary GC column ordering part number (100-2000), used to order custom-configured DB/HP capillary GC columns, non-standard lengths or film thicknesses, integrated DuraGuard guard columns, or Low Thermal Mass (LTM) column modules tailored to specific analytical needs.
Request a quote →
Gooneex
11252
Protective ring for Sotax AT7 Smart vessels -6 pc/PAK
Protective ring designed for Sotax AT7 Smart 1000 mL dissolution vessels to protect the vessel flange rim against chipping and breaking during handling and bath installation.
Request a quote →
Gooneex
160-2535-5
Fused silica tubing, deactivated, 5 m, 0.53 mm, 0.67 mm od
Agilent deactivated fused silica tubing (5 m length, 0.53 mm ID, 0.67 mm OD) designed for use as a retention gap, guard column, or headspace transfer line in gas chromatography systems.
Request a quote →
Gooneex
18710-60170
FID/TCD performance evaluation sample kit
FID/TCD performance evaluation sample kit containing C14, C15, and C16 normal hydrocarbons (0.033% w/w each in hexane) in three 0.5 mL ampoules, designed for routine FID/TCD detector performance checks and calibration on gas chromatographs.
Request a quote →