RT600 Dissolution Apparatus
RT600

RT600 Dissolution Apparatus

The RT600 is an 8-position, single drive, manual sampling dissolution tester. It fully meets the testing requirements in Chp (0931), USP (711/724), EP (2.9.3/4). Automatic dosing, automatic positioning, real-time display of speed and temperature can be realized. No upper limit of storage space. Meeting the needs of high-precision measurement and ease of operation.

  • Covered Dissolving Cups
  • Convenient Sampling
  • Automatic Synchronous Dosing
  • Infinite Data Storage

Key features

Automatic preheating

With the automatic preheating function of medium, the instrument can be set to automatically start constant temperature water bath heating at the specified time.

Convenient sampling

Non-resident sampling needles to reduce turbulence generation. The sampling needle can be automatically positioned according to the set solvent volume.

Covered Dissolving Cups

Dissolving cups are automatically centered for fast and accurate installation and greater durability.

Paddle basket co-axial design

Suitable for all kinds of regulations included in the test method. Not necessary to readjust the height of dissolution unit after switching dissolution method.

Round corner water bath

The one-piece, rounded corner design of the water bath ensures that there are no dead corners in the water circulation for heating and cleaning.

Automatic Synchronous Dosing

Eliminate the time difference of dosing, and the time point of dosing can be tracked.

Applications

Basket and paddle methods are the most commonly used legal dissolution methods in national pharmacopoeias and were the first dissolution methods introduced into pharmacopoeias. They are mainly used for quality control (QC) of pharmaceutical products.

  • Oral Tablets
  • Patch
  • Semi-solid preparations
  • Injection
  • Intrinsic Dissolution Rate of API

Technical specifications

General Dissolution System
Length ×Width× Height(Fully Raised)
~ 63 cm × 56cm ×96 cm
Dissolution Vessel Number
8
Setting Range
0-300 rpm (RPM)
RPM Resolution
0.01RPM
Steady Speed Error
≤±0.3RPM
Temp. Accuracy
≤±0.2℃
Temp. Resolution
0.01 ℃
Level
< 0.5°
Vessel Verticality
90°±0.5°
Shaft Verticality
90°±0.5°
Centering Deviation
< ±2.0 mm
Depth Positioning Deviation
< ±1.0 mm
Shaft Wobble
< ±1.0 mm
Basket Wobble
< ±1.0 mm
Operating System
—
Meeting FDA21 CFR Part 11