RT3 Reciprocating Cylinder Apparatus
RT300 (RT3)

RT3 Reciprocating Cylinder Apparatus

The RT3 Reciprocating Cylinder operates as an advanced dissolution testing equipment that duplicates in vivo mechanical stress conditions by offering exact control of bicurious motions. The device integrates an automatic vessel cover which reduces evaporation losses while offering single-piece water baths that promote efficient heating. Users can modify the reciprocating stroke together with the rate and immersion time through flexible settings accessible by the system. A precise filtration device with high accuracy filters drug matter to generate proper test results. The device operates through an 8.4-inch touchscreen interface that makes operation easy by meeting all requirements from FDA 21 CFR Part 11.

  • Efficient Anti-volatilization
  • Low Operational Noise
  • Flexible Reciprocating Parameterization
  • Intimate Operation Design

Key features

Co-axial Mounting Bracket

The coaxial split design makes it quickly to replace the reciprocating cylinder with other reciprocating holder.

Automatic Dissolution Vessel Cover

The cover of dissolution vessel can automatically open and close, effectively reducing the evaporation loss of the dissolution medium.

One-piece water bath

One-piece rounded corners water bath with no dead spots and can be thoroughly drained

Filtration device

Various sizes of cylindrical filter elements can be fitted to filter out large particles of drugs that are not fully dissolved.

Flexible setting of experimental parameters

The reciprocating rate, reciprocating stroke, immersion time and drain time can be set.

Wide range of dissolution vessel sizes

Available with 300mL or optional 1000mL dissolving cup for testing.

User-computer Interface

8.4-inch touch screen, preinstalled with the Raytor dissolution operating system, meeting the data integrity requirements.

Applications

  • Functional Gummies
  • Enteric tablets
  • Soft capsule
  • orally disintegrating tablets

Technical specifications

Reciprocating Cylinder Dissolution System
Length ×Width× Height(Fully Raised)
80cm × 63cm ×100 cm
Dissolution Vessel Row Number
7 tubes ×6 Rows(300mL Stand Vessel)
Dissolution System Level
≤ 0.3°
Shaft Verticality
≤ 90°± 0.5°
Temperature Control Range
Ambient Temperature ~ 50℃
Temp. Resolution
0.1 ℃
Temp. Accuracy
≤ ± 0.2℃
Vessels’ Temp. Difference
≤ ± 0.5℃
Adjustable Range of Reciprocating Stroke
2 ~ 10 cm
Error of Reciprocating Stroke
≤ ± 0.1 cm
Adjustable Range of Reciprocating Rate
4 ~ 60 DPM
Error of Reciprocating Rate
≤ ±5%
Maximum Running Time
600 (Hours)
Operating System
—
Meet the requirements of  FDA21 CFR Part 11
Official Raytor product page