GBP/USD1.2734 0.0042|EUR/USD1.0851 0.0019|GBP/EUR1.1736 0.0028|DXY104.21 0.18|FTSE 1008,224.31 18.42|GBP/USD1.2734 0.0042|EUR/USD1.0851 0.0019|GBP/EUR1.1736 0.0028|DXY104.21 0.18|FTSE 1008,224.31 18.42|
Home / HPLC Parts / Hitachi
HPLC Parts Supply

Hitachi HPLC Parts & Spare Components

Advanced Life Sciences supplies Hitachi HPLC parts and components for liquid chromatography systems, with quotations by part number for laboratories in the United Kingdom, United States and Brazil. Fornecemos peças para HPLC Hitachi e cromatografia líquida, com cotação direta por Part Number (PN).

Hitachi part numbers (40)

Hitachi
080-3276
Hitachi Syringe Tip, 0.5 ml for LaChromUltra L-2200U Autosampler, 1/Pk
Replacement 0.5 ml PTFE plunger tip (syringe seal) for Hitachi HPLC autosampler syringes, designed to provide leak-tight sealing and precise liquid delivery in autosampler dosing syringes.
Request quote →
Hitachi
0890-1763
Tubing, PEEK, 1.6 mm od, 0.18 mm id, 1.5 m. Yellow
Flexible yellow PEEK tubing for HPLC/UHPLC/IC applications, featuring an outer diameter of 1.6 mm (1/16 in), inner diameter of 0.18 mm (0.007 in), and length of 1.5 m. Delivers bio-inert, high-pressure fluid transfer.
Request quote →
Hitachi
638-1423
FILTER
Hitachi 638-1423 is a flow path filter (drain/purge valve filter) for Hitachi HPLC pumps. It traps particulates in mobile phases to protect downstream chromatographic components, maintaining consistent pressure and solvent flow.
Request quote →
Hitachi
655-1080
Seal for Chromaster 5110 Pumps, LaChromElite L-2130, Primaide PM1110, 1/Pk
Unit: Un
Request quote →
Hitachi
810-1004
Valve Assembly (Assy) LaChromElite
Inlet Check Valve Assembly for Hitachi HPLC pumps. Prevents solvent backflow on the suction side during piston strokes to maintain accurate flow rates and stable system pressure.
Request quote →
Hitachi
810-1128
PACKING, DRAIN VALVE,1
Replacement OEM drain valve packing seal for Hitachi HPLC solvent delivery pump drain and purge valves, engineered to prevent solvent leaks and maintain system pressure.
Request quote →
Hitachi
810-1344
packing (A)
Hitachi Packing (B) (PN 810-1344) is a thick black valve flat gasket (OD 6.0 mm, thickness 2.0 mm) for check valve and pump head assemblies in Hitachi HPLC pumps, including LaChrom L-7100, LaChrom Elite L-2130, Primaide PM1110, and Chromaster 5110.
Request quote →
Hitachi
810-1345
Packing (2) for Chromaster 5110, 5160, LaChromElite L-2130, Primaide PM1110 Pumps, 4/Pk
Hitachi Packing (2) (PN 810-1345) is an authentic thin black valve seal packing for check valve assemblies in Hitachi HPLC pumps. It ensures leak-free liquid sealing and consistent solvent delivery pressure in analytical chromatography systems.
Request quote →
Hitachi
810-3095
HITACHI VALVE SEAL
The Hitachi 810-3095 is an OEM diluter valve seal designed for injection and diluter valve assemblies in Hitachi HPLC autosamplers. It ensures fluidic integrity and leak-free performance during automated sample processing.
Request quote →
Hitachi
810-3927
Flow Cell 12 ul for LaChromElite L-2480 Fluorescence Detector 1/Pk
12 µl flow cell designed for use with Hitachi LaChrom Elite L-2480 fluorescence detectors in High-Performance Liquid Chromatography (HPLC) systems.
Request quote →
Hitachi
890-1192
Hitachi Light Guide L-2100, L-2130, L-2200, L-2400, L-2420, L-2450, L-2480, 1/Pk
Hitachi optical light guide (PN 890-1192) designed for LaChrom Elite HPLC series modules including pumps, autosamplers, and detectors.
Request quote →
Hitachi
890-2019
HAMAMATSU - Xenon Lamp, 150W for L-2175
Unit: Un
Request quote →
Hitachi
890-2289
HITACHI HIGH TECHNOLOGIES,TUBE ASSEMBLY, INLET
Inlet tube assembly for Hitachi HPLC diode array detectors (DAD). Connects HPLC flow line to detector flow cell for precise sample transport in chromatography applications.
Request quote →
Hitachi
890-2527
Hitachi Halogen Lamp (20W)
Unit: Un
Request quote →
Hitachi
890-3183
Injection Port Seal for LaChromElite L-2200 Autosampler, 1/Pk
Injection port seal (PEEK material) designed for Hitachi LaChrom Elite L-2200 HPLC autosamplers, ensuring leak-free sealing at the needle-to-port interface.
Request quote →
Hitachi
890-3243
SEAL INJECTION VALVE ROTOR
The Hitachi 890-3243 is a replacement PEEK injection valve rotor seal for Hitachi HPLC autosamplers. It provides high-pressure, leak-tight sealing during valve rotation and directly replaces OEM part number 890-3238.
Request quote →
Hitachi
890-3984
PE Tip
Plunger tip replacement seal for 0.1 mL (100 µL) autosampler dosing syringe (PN 890-3228) used in Hitachi LaChrom Elite HPLC systems.
Request quote →
Hitachi
890-4935
Primaide PM1430 DAD EU Plug, 1/P
Toroidal Mirror Assembly A for Hitachi HPLC Diode Array Detectors (DAD), used in the optical bench to focus light into the flow cell and diode array spectrometer.
Request quote →
Hitachi
890-6725
Photo Interrupter SY for LaChromElite L-2200 Autosampler, 1/Pk
Photo Interrupter SY optical sensor assembly for Hitachi LaChrom Elite L-2200 Autosampler. Used for precise position sensing during automated HPLC sample injection cycles.
Request quote →
Hitachi
890-6727
Hitachi Photo Interrupter SV for LaChromElite L-2200 Autosampler, 1/Pk
Hitachi Photo Interrupter SV (PN 890-6727) is an optical position sensor designed for the LaChromElite L-2200 HPLC Autosampler. It detects mechanical axis/valve positions to ensure accurate sample loading and system timing.
Request quote →
Hitachi
890.9999
Maintenance parts kit for LaChrom Elite
Unit: Un
Request quote →
Hitachi
891-0702
USB IF BOARD
An internal communication interface board manufactured by Hitachi for HPLC analytical systems. It enables USB communication and data transfer between Hitachi liquid chromatography modules (pumps, autosamplers, detectors) and a control PC running chromatography management software.
Request quote →
Hitachi
891-1213
Hitachi Plunger Seal for Chromaster 5160
High-pressure plunger seal designed for Hitachi Chromaster 5160 and LaChromUltra L-2160U HPLC/UHPLC pumps operating up to 600 bar. Prevents mobile phase solvent leakage along the piston shaft during high-pressure liquid chromatography runs.
Request quote →
Hitachi
891-1364
Hitachi Packing (B) for Chromaster 5160 Pumps
Hitachi Packing (B) (PN 891-1364) is an OEM replacement valve flat packing seal designed for Hitachi Chromaster 5160 and LaChromUltra L-2160U liquid chromatography pumps to maintain leak-free pressure sealing in solvent delivery flow paths.
Request quote →
Hitachi
891-3954
HIGH TECHNOLOGIES,0.1ML SYRINGE PE,1
0.1 mL Polyethylene (PE) syringe designed for Hitachi HPLC autosamplers. Serves as a direct replacement for part number 891-3958, providing precise sample aspiration and volumetric accuracy in liquid chromatography systems.
Request quote →
Hitachi
891-3964
PE Tip
Polyethylene (PE) replacement plunger seal tip for 0.1 mL (100 µL) autosampler syringes used in Hitachi HPLC systems.
Request quote →
Hitachi
892-0274
Sample loop (200 µl) for Chromaster HPLC 5260 and 5210 autosamplers
Unit: Un
Request quote →
Hitachi
892-0893
Kit de Peças de Manutenção para Chromaster HPLC 5110
Maintenance parts kit designed for Hitachi Chromaster 5110 HPLC pumps. Includes essential replacement seals, packings, and filters required for routine preventive maintenance to ensure optimal pump sealing, flow accuracy, and pressure stability.
Request quote →
Hitachi
892-0894
Maintenance Parts Kit For Chromaster HPLC 5160 Pumps
Comprehensive OEM preventive maintenance parts kit for Hitachi Chromaster 5160 HPLC pumps. Includes primary pump seals, wash seals, drain valve seals, packings, and flow path filters required for routine pump servicing and optimal fluidic performance.
Request quote →
Hitachi
892-0895
Kit de Peças de Manutenção Hitachi para Autos amostradores HPLC Chromaster 5210, Tipo A
Hitachi Maintenance Parts Kit (PN 892-0895), Type A, for Chromaster HPLC 5210 autosamplers. Kit includes replacement seals and syringe tips required for routine preventative maintenance.
Request quote →
Hitachi
892-2550
Hitachi Deuterium Lamp
Unit: Un
Request quote →
Hitachi
893-0808
syringe tip
Hitachi 175 µL PTFE syringe tip (plunger seal) for Chromaster 5210 and 5260 HPLC autosampler syringes. OEM PN 893-0808 (superseded by 893-0818).
Request quote →
Hitachi
893-0810
Hitachi Injection Port Seal for Chromaster 5210, 5260 Autosamplers
Hitachi Injection Port Seal (PN 893-0810) designed for Chromaster 5210 and 5260 HPLC autosamplers. Ensures leak-free sealing around standard sample injection needles in liquid chromatography systems.
Request quote →
Hitachi
893-0814
Hitachi Syringe Valve Seal for Chromaster
Hitachi Syringe Valve Seal (PN 893-0814) designed for Chromaster HPLC autosamplers. Ensures reliable, leak-free liquid sealing within the syringe valve assembly to maintain flow accuracy and prevent sample contamination.
Request quote →
Hitachi
893-0818
Syringe Tip, for 175 ul Syringe, for Chromaster 5210, 5260 Autosamplers
Replacement PTFE syringe plunger seal (tip) for 175 µl diluter syringes used in Hitachi Chromaster HPLC autosamplers. Ensures leak-tight liquid dispensing and sample aspiration.
Request quote →
Hitachi
893-0912
Válvula de retenção Hitachi para sistemas HPLC Chromaster.
Replacement Vespel injection valve seal designed for Hitachi Chromaster 5260 HPLC autosamplers (600 bar). Ensures leak-free operation and optimal switching performance in high-pressure sample injection valves.
Request quote →
Hitachi
893-0962
Maintenance Parts Kit for L-2200
Unit: Un
Request quote →
Hitachi
893-4755
Lâmpada Deuterium D2 - Hitachi
Unit: UN
Request quote →
Hitachi
9027.90.99
Hitachi Photo Interrupter SY for LaChromElite L-2200 Autosampler,
Transmissive optical sensor assembly (photointerrupter SY) for Hitachi LaChromElite L-2200 HPLC Autosamplers, used for mechanical position sensing and tray/arm alignment.
Request quote →
Hitachi
VWR810-1345
Packing (2) for Chromaster 5110, 5160, LaChromElite L-2130, Primaide PM1110 Pumps,1/Pk
VWR Hitachi Packing (2) / Packing (A) is a replacement valve seal gasket for Hitachi HPLC pump check valve assemblies. Compatible with Chromaster 5110/5160, LaChrom Elite L-2130, LaChrom L-7100/L-7110, and Primaide PM1110 pumps. Pack of 1.
Request quote →